KAMAN KDM-8206 REFERENCE MANUAL Pdf Download (2024)

  1. Manuals
  2. Brands
  3. Kaman Manuals
  4. Measuring Instruments
  5. KDM-8206
  6. Reference manual

Non-contact displacement measuring system, 1/2 rack instrumentation case (3u/42hp), 3/4 rack instrumentation case (3u/63hp), full 19" sub-rack (3u/84hp)

Hide thumbs

1
Table Of Contents 2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
  • Contents
  • Table of Contents
  • Bookmarks

Table of Contents

  • Table of Contents

  • Part 1 Introduction

  • Figure 1 Rear Panel I/O

  • Part 2 Rear Panel Connections

  • Part 3 Measuring Channel Connections

    • Back Plane PCB

    • Figure 2 Measuring Channel Back Plane PCB, Front View

    • Figure 3 Measuring Channel Back Plane PCB, Rear View

    • Back Panel PCB

    • Figure 4 Back Panel PCB

  • Figure 5 Display Module Front Panel

  • Part 4 Optional Display Module

  • Figure 6 Display Module Back Plane PCB, Front View

  • Figure 7 Display Module Back Plane PCB, Rear View

  • Figure 8 Back Panel P4 Jumper Configuration

  • Part 5 Enclosures

    • Full 19" Instrumentation Sub-Rack - 3U/84HP

    • Figure 9 Full 19" Sub-Rack Side Outline Drawing

    • Figure 10 Full 19" Sub-Rack Rear / Front Outline Drawing

    • Figure 11 Full 19" Sub-Rack Top View Outline Drawing

    • Figure 12 Full 19" Sub-Rack Front/Top with Display

    • 1/2 Rack Instrumentation Enclosure - 3U/42HP

    • Figure 13 1/2 Rack Front View Outline Drawing

    • Figure 14 1/2 Rack Rear View Outline Drawing

    • Figure 15 1/2 Rack Side/Top View Outline Drawing

    • Figure 16 1/2 Rack Top View with Display

    • 3/4 Rack Instrumentation Enclosure - 3U/63HP

    • Figure 17 3/4 Rack Front View Outline Drawing

    • Figure 18 3/4 Rack Rear View Outline Drawing

    • Figure 19 3/4 Rack Side/Top View Outline Drawing

    • Figure 20 3/4 Rack Top View with Display

  • Part 6 Integral Power Supply

    • Power Supply

    • Power Entry Module

    • Figure 21 Power Supply

    • Figure 22 Power Entry Module

  • Appendix Areplacement or Expansion Parts

Advertisem*nt

Quick Links

Download this manual

Non-Contact Displacement Measuring

1/2 Rack Instrumentation Case (3U/42HP)

3/4 Rack Instrumentation Case (3U/63HP)

Copyright © 2014

PART NO: 860515-001

Last Revised 12/05/14

KDM-8206

System

Rack Reference Manual

Full 19" Sub-Rack (3U/84HP)

Kaman Precision Products

A Division of Kaman Aerospace Corporation

217 Smith Street

Middletown, CT 06457

www.kamansensors.com

Table ofContents

NextPage
  • 1
  • 2
  • 3
  • 4
  • 5

Advertisem*nt

Table of Contents

KAMAN KDM-8206 REFERENCE MANUAL Pdf Download (1)

Related Manuals for Kaman KDM-8206

  • Measuring Instruments Kaman KD-2306 User Manual

    Non-contact displacement measuring system (20 pages)

  • Measuring Instruments Kaman KD-5100 User Manual

    Differential (36 pages)

  • Measuring Instruments Kaman ThreadChecker User Manual

    Noncontact thread detection system (12 pages)

Summary of Contents for Kaman KDM-8206

  • Page 1 3/4 Rack Instrumentation Case (3U/63HP) Full 19" Sub-Rack (3U/84HP) Copyright © 2014 Kaman Precision Products PART NO: 860515-001 A Division of Kaman Aerospace Corporation Last Revised 12/05/14 217 Smith Street Middletown, CT 06457 www.kamansensors.com ...
  • Page 2: Table Of Contents

    Table of Contents PART 1 INTRODUCTION ....................4 PART 2 REAR PANEL CONNECTIONS ................ 5 PART 3 MEASURING CHANNEL CONNECTIONS ............6 3.1 Back Plane PCB ....................6 3.2 Back Panel PCB ....................8 PART 4 OPTIONAL DISPLAY MODULE ............... 9 PART 5 ENCLOSURES ....................
  • Page 3 List of Figures Figure 1 Rear Panel I/O ....................5 Figure 2 Measuring Channel Back Plane PCB, Front View ........6 Figure 3 Measuring Channel Back Plane PCB, Rear View ......... 7 Figure 4 Back Panel PCB .................... 8 Figure 5 Display Module Front Panel ................
  • Page 4: Part 1 Introduction

    PART 1 - INTRODUCTION The KDM-8206 is a modular packaging system for Kaman Precision Products’ line of inductive displacement transducer electronics. The KDM-8206 enclosures integrate various measuring channels, power supplies, and displays into a coherent application specific industrial package. Sensors for the measuring channels are available that...
  • Page 5: Part 2 Rear Panel Connections

    PART 2 - REAR PANEL CONNECTIONS Refer to Figure 1 below. Twin BNC connectors on the bottom row are for connecting the Sensors to the rack or enclosure. The rack was configured at the factory to enable the measuring channel to use a single coil or dual coil sensor. If a measuring channel is being changed from a single coil sensor to a dual coil sensor, it will be necessary to add an additional RF cable between the measuring channel backplane board and backpanel board.
  • Page 6: Part 3 Measuring Channel Connections

    PART 3 - MEASURING CHANNEL CONNECTIONS Internal wiring for each Measuring Channel in a rack or instrument enclosure is in modular format. Each Measuring Channel requires: • A Back Plane PCB to connect to the Measuring Channel • A Back Panel PCB for sensor input and analog voltage or current output •...
  • Page 7: Figure 3 Measuring Channel Back Plane Pcb, Rear View

    P1 P4 P3 JB JA SIN SOUT Figure 3 Measuring Channel Back Plane PCB, Rear View There are two versions of the Back Plane PCB. The Channel 1 version is installed in the channel 1 position only.
  • Page 8: Back Panel Pcb

    3.2 Back Panel PCB The Back Panel PCB is installed in the rack just as its name indicates, to the rear panel of the rack or instrument enclosure. It is secured to the rear panel with three flat head screws and with the BNC connector nuts.
  • Page 9: Part 4 Optional Display Module

    Ground) of the Measuring Channel selected. For the meter to display differential output (the difference between V+ and V- Outputs), jumper J7 on the KDM-8206 Measuring Channel must be changed from positions 1 and 2 to positions 2 and 3 . (Reference the KDM-8206 System User’s Manual)
  • Page 10: Figure 6 Display Module Back Plane Pcb, Front View

    J1 P3 Figure 6 Display Module Back Plane PCB, Front View P1 Figure 7 Display Module Back Plane PCB, Rear View www.kamansensors.com PART NO: 860515-001 Last Revised: 3/12/2013...
  • Page 11: Figure 8 Back Panel P4 Jumper Configuration

    For Figures 6 and 7 above, the connections labeled are: • J1 connects to the back plane PCB of Measuring Channel No. 1 • P1 input DC power from rack power supply • P3 ribbon cable connection to the front panel display module To configure the rack enclosure for the Display Module, jumpers need to be set on terminal strip P4 on the Back Panel PCB of each Measuring Channel.
  • Page 12: Part 5 Enclosures

    Measuring Channels in place. Use of a sub-Rack enables installation of the KDM-8206 system into a standard 19" test equipment rack. The sub-Rack normally includes a built in 120VAC/240VAC power supply to provide ±15VDC required by the Measuring Channels.
  • Page 13: Figure 10 Full 19" Sub-Rack Rear / Front Outline Drawing

    Figure 10 Full 19" Sub-Rack Rear / Front Outline drawing www.kamansensors.com PART NO: 860515-001 Last Revised: 3/12/2013...
  • Page 14: Figure 11 Full 19" Sub-Rack Top View Outline Drawing

    Figure 11 Full 19" Sub-Rack Top View Outline Drawing www.kamansensors.com PART NO: 860515-001 Last Revised: 3/12/2013...
  • Page 15: Figure 12 Full 19" Sub-Rack Front/Top With Display

    Figure 12 Full 19" Sub-Rack Front/Top with Display www.kamansensors.com PART NO: 860515-001 Last Revised: 3/12/2013...
  • Page 16: 1/2 Rack Instrumentation Enclosure - 3U/42Hp

    5.2 1/2 Rack Instrumentation Enclosure - 3U/42HP The 1/2 rack instrument case is a fully enclosed stand-alone enclosure for the KDM- 8206 system with a tilt bar to elevate the front of the case. The instrument case has an integral 120VAC/240VAC power supply to provide ±15VDC required by the Measuring Channels.
  • Page 17: Figure 13 1/2 Rack Front View Outline Drawing

    Figure 13 1/2 Rack Front View Outline Drawing www.kamansensors.com PART NO: 860515-001 Last Revised: 3/12/2013...
  • Page 18: Figure 14 1/2 Rack Rear View Outline Drawing

    Figure 14 1/2 Rack Rear View Outline Drawing www.kamansensors.com PART NO: 860515-001 Last Revised: 3/12/2013...
  • Page 19: Figure 15 1/2 Rack Side/Top View Outline Drawing

    Figure 15 1/2 Rack Side/Top View Outline Drawing www.kamansensors.com PART NO: 860515-001 Last Revised: 3/12/2013...
  • Page 20: Figure 16 1/2 Rack Top View With Display

    Figure 16 1/2 Rack Top View With Display www.kamansensors.com PART NO: 860515-001 Last Revised: 3/12/2013...
  • Page 21: 3/4 Rack Instrumentation Enclosure - 3U/63Hp

    5.3 3/4 Rack Instrumentation Enclosure - 3U/63HP The 3/4 rack instrument case is a fully enclosed stand-alone enclosure for the KDM- 8206 system with a tilt bar to elevate the front of the case. The instrument case has an integral 120VAC/240VAC power supply to provide ±15VDC required by the Measuring Channels.
  • Page 22: Figure 18 3/4 Rack Rear View Outline Drawing

    Figure 18 3/4 Rack Rear View Outline Drawing www.kamansensors.com PART NO: 860515-001 Last Revised: 3/12/2013...
  • Page 23: Figure 19 3/4 Rack Side/Top View Outline Drawing

    Figure 19 3/4 Rack Side/Top View Outline Drawing www.kamansensors.com PART NO: 860515-001 Last Revised: 3/12/2013...
  • Page 24: Figure 20 3/4 Rack Top View With Display

    Figure 20 3/4 Rack Top View With Display www.kamansensors.com PART NO: 860515-001 Last Revised: 3/12/2013...
  • Page 25: Part 6 Integral Power Supply

    (100 to 240VAC). Unplug the unit before servicing. 6.1 Power Supply The power supply for the KDM-8206 rack enclosures is integral to the chassis and mounted internally on the side panel. The KDM-8206 power supply provides a ± 15VDC regulated output. The same power supply is utilized for the Full 19” Sub-Rack, the 1/2 Rack Instrument Enclosure, and the 3/4 Rack Instrument Enclosure.
  • Page 26: Power Entry Module

    G2 L J1 N G3 G1 Figure 21 Power Supply 6.2 Power Entry Module The power entry module provides an on/off switch and a fuse receptacle. If it becomes necessary to replace the fuses refer to Appendix A for the replacement part number. Use a small flat tip screwdriver or suitable instrument to pry the fuse receptacle out of the power entry module when replacing the fuses.
  • Page 27: Appendix Areplacement Or Expansion Parts

    APPENDIX A REPLACEMENT OR EXPANSION PARTS Kaman P/N Description 827286-022G FUSE 2.5A 250V T-LAG 5 X 20 MM 816619-100G ASSEMBLY PANEL BLANK FRONT 7HP 816620-100G KIT PANEL BLANK REAR 827322-006G CABLE, RF SMA M/M 6 INCH 827325-G2406G CABLE, RIBBON 28 AWG 24 COND 6 INCH...
KAMAN KDM-8206 REFERENCE MANUAL Pdf Download (2024)

References

Top Articles
Latest Posts
Article information

Author: Neely Ledner

Last Updated:

Views: 6276

Rating: 4.1 / 5 (42 voted)

Reviews: 81% of readers found this page helpful

Author information

Name: Neely Ledner

Birthday: 1998-06-09

Address: 443 Barrows Terrace, New Jodyberg, CO 57462-5329

Phone: +2433516856029

Job: Central Legal Facilitator

Hobby: Backpacking, Jogging, Magic, Driving, Macrame, Embroidery, Foraging

Introduction: My name is Neely Ledner, I am a bright, determined, beautiful, adventurous, adventurous, spotless, calm person who loves writing and wants to share my knowledge and understanding with you.